LYSAGHT® Cold Formed Sections

Product Description and Features

LYSAGHT® Cold Formed Sections are roll-formed from zinc coated and uncoated material.  The strength of LYSAGHT® Cold Formed Sections has been increased from 240 and 250MPa to 300MPa for both the zinc coated and uncoated products, increasing the structural capacity of the steel channel and angle sections.  These sections have many uses in the construction, general fabrication and home handyman fields.

  • Many combinations of sections are possible
  • Sizes of several plain channels enables them to nest readily
  • Normal box sections are easily fabricated
  • Machine controlled dimensions allow a neat fit and provide an easy method of assembly for sliding joints
  • Able to be welded or bolted.
Note:
  • Cold formed steel channels and angles will perform as specified if design, fabrication and fixing are in accordance with our recommendations
  • If it is intended to use cold formed steel channels and angles in exposed situations within 1km of salt marine locations, or in severe industrial or unusually corrosive environments, please contact us.

Brochures

LYSAGHT® Cold Formed Sections CFS-II Safe Load Tables

LYSAGHT® Cold Formed Sections CFS-I Section Properties

This search will find the ten closest suppliers for the location you enter, for the selected product. Fill in each of the fields below, then click "SEARCH"

Please note this locator only contains suppliers in AUSTRALIA. If you need suppliers in other countries please contact your local BlueScope Steel office.

Fields marked with * are required

Specification

BlueScope Lysaght cold formed steel channels and angles are available either zinc coated or uncoated in base metal thicknesses (BMT) of 1.0 mm, 1.6 mm, 2.5 mm and 3.0 mm depending on section type. The materials used are zinc coated steel to AS 1397-2001 G300-Z275 (300 MPa minimum yield stress, 275g/m2 minimum average coating mass) and uncoated steel to AS/NZS 1594-2002 HA300 (300 MPa minimum yield stress).

In addition, subject to minimum quantity order, BlueScope Lysaght cold formed steel channels and angles can be produced from higher yield stress uncoated and zinc coated steels to meet more demanding design requirements.

Physical Properties

Plain Channels

Tolerances
Web: + 2 mm -1 mm for LC 12730, LC 15230
± 1 mm for all other sections.
Flange: ± 2 mm
Length: ± 15 mm

Method of Cataloguing
Plain Channels are denoted by the letters "LC". In the number following these letters, the first three digits indicate the nominal web dimension of the channel in millimetres. The last two digits indicate the thickness of material in tenths of a millimetre, eg.
LC 05130 - Plain Channel, 51 mm x 3.0 mm.

Download LYSAGHT® Cold Formed Section Plain Channel Dimensions Table (78 KB)


Lipped Channels

Tolerances
Web: ± 1 mm for LL 06425 to LL 10230
+ 2 mm -1 mm for LL 12725 to LL 25430
Flange: ± 1 mm for LL 06425 to LL 10230 (within 1mm each side)
+ 2 mm -1mm for LL 12725 to LL 25430 (within 1mm each side).
Length: ± 15 mm - 0

Method of Cataloguing
Lipped Channels are denoted by the letters "LL". In the number following these letters, the first three digits indicate the nominal web dimension of the channel in millimetres. The last two digits indicate the thickness of material in tenths of a millimetre, eg.
LL 06425 - Lipped Channel 364 mm x 2.5 mm.
LC 20330 - Lipped Channel 203 mm x 3.0 mm.

Download LYSAGHT® Cold Formed Section Lipped Channel DimensionsTable (98 KB)


Plain Channels (Nested)
(toe to toe)
(back to back)

Download LYSAGHT® Cold Formed Section Nested Plain Channel Dimensions Table (72 KB) 


Lipped Channels (Nested)
(toe to toe)
(back to back)

Download LYSAGHT® Cold Formed Section Nested Lipped Channel Dimensions Table (90 KB)

Angles

Tolerances
Legs: ± 1.5 mm, equal within 1 mm for equal anges.
Length: ± 15 mm - 0

Packing
40 lengths per bundle.

Method of Cataloguing
Angles are denoted by the letters "LA". In the number following these letters, the first two digits indicate the dimensions of the longer leg of the angle in millimetres. The last two digits indicate the thickness of material in tenths of a millimetre, eg.
LA 4630 - Angle 46 mm x 3.0 mm.

Download LYSAGHT® Cold Formed Section Angles Dimensions Table (90 KB)

 

Disclaimer

 

 

Availability

NSW/
ACT
VICTASQLDNTSAWA
Avail.Avail.Avail.Not Avail.Avail.Avail.Avail.

*Please contact our sales office on 13 30 38 for availability.

 

Brochures

LYSAGHT® Cold Formed Sections CFS-II Safe Load Tables

LYSAGHT® Cold Formed Sections CFS-I Section Properties


Specification

Specification

BlueScope Lysaght cold formed steel channels and angles are available either zinc coated or uncoated in base metal thicknesses (BMT) of 1.0 mm, 1.6 mm, 2.5 mm and 3.0 mm depending on section type. The materials used are zinc coated steel to AS 1397-2001 G300-Z275 (300 MPa minimum yield stress, 275g/m2 minimum average coating mass) and uncoated steel to AS/NZS 1594-2002 HA300 (300 MPa minimum yield stress).

In addition, subject to minimum quantity order, BlueScope Lysaght cold formed steel channels and angles can be produced from higher yield stress uncoated and zinc coated steels to meet more demanding design requirements.

Physical Properties

Plain Channels

Tolerances
Web: + 2 mm -1 mm for LC 12730, LC 15230
± 1 mm for all other sections.
Flange: ± 2 mm
Length: ± 15 mm

Method of Cataloguing
Plain Channels are denoted by the letters "LC". In the number following these letters, the first three digits indicate the nominal web dimension of the channel in millimetres. The last two digits indicate the thickness of material in tenths of a millimetre, eg.
LC 05130 - Plain Channel, 51 mm x 3.0 mm.

Download LYSAGHT® Cold Formed Section Plain Channel Dimensions Table (78 KB)


Lipped Channels

Tolerances
Web: ± 1 mm for LL 06425 to LL 10230
+ 2 mm -1 mm for LL 12725 to LL 25430
Flange: ± 1 mm for LL 06425 to LL 10230 (within 1mm each side)
+ 2 mm -1mm for LL 12725 to LL 25430 (within 1mm each side).
Length: ± 15 mm - 0

Method of Cataloguing
Lipped Channels are denoted by the letters "LL". In the number following these letters, the first three digits indicate the nominal web dimension of the channel in millimetres. The last two digits indicate the thickness of material in tenths of a millimetre, eg.
LL 06425 - Lipped Channel 364 mm x 2.5 mm.
LC 20330 - Lipped Channel 203 mm x 3.0 mm.

Download LYSAGHT® Cold Formed Section Lipped Channel DimensionsTable (98 KB)


Plain Channels (Nested)
(toe to toe)
(back to back)

Download LYSAGHT® Cold Formed Section Nested Plain Channel Dimensions Table (72 KB) 


Lipped Channels (Nested)
(toe to toe)
(back to back)

Download LYSAGHT® Cold Formed Section Nested Lipped Channel Dimensions Table (90 KB)

Angles

Tolerances
Legs: ± 1.5 mm, equal within 1 mm for equal anges.
Length: ± 15 mm - 0

Packing
40 lengths per bundle.

Method of Cataloguing
Angles are denoted by the letters "LA". In the number following these letters, the first two digits indicate the dimensions of the longer leg of the angle in millimetres. The last two digits indicate the thickness of material in tenths of a millimetre, eg.
LA 4630 - Angle 46 mm x 3.0 mm.

Download LYSAGHT® Cold Formed Section Angles Dimensions Table (90 KB)

 

Disclaimer

 

 

Availability

Availability

NSW/
ACT
VICTASQLDNTSAWA
Avail.Avail.Avail.Not Avail.Avail.Avail.Avail.

*Please contact our sales office on 13 30 38 for availability.

 



 
BlueScope Steel Limited
ABN 16 000 011 058
BlueScope is a trademark
of BlueScope Steel Limited