LYSAGHT KLIP-LOK MAXIMA® is a wide cover concealed fixed cladding. It has extra wide 770mm coverage with excellent performance. It features strong ribs rising from flat pans. Because of the ease of installation and the extra economy 770mm wide cover brings, you get outstanding value.
This search will find the ten closest suppliers for the location you enter, for the selected product. Fill in each of the fields below, then click "SEARCH"
Please note this locator only contains suppliers in AUSTRALIA. If you need suppliers in other countries please contact your local BlueScope Steel office.
Fields marked with * are required
You may choose to Search for Supplier by Name
| NSW/ ACT | VIC | TAS | QLD | NT | SA | WA |
|---|---|---|---|---|---|---|
| Not Avail. | Not Avail. | Not Avail. | Not Avail. | Not Avail. | Not Avail. | Avail. |
LYSAGHT KLIP-LOK MAXIMA® is available in the standard range of COLORBOND® steel colours and in unpainted ZINCALUME® steel.
Please check with your local supplier regarding specific colour availability for this product.
The maximum recommended support spacings are based on testing in accordance with AS1562.1-1992, AS4040.1-1992 and AS4040.2-1992. Supports must not be less than 1mm BMT.
Roof spans consider both resistance to wind pressure and light roof traffic (traffic arising from incidental maintenance).
Wall spans consider resistance to wind pressure only.
The figures relate only to buildings 10m or less in height and located in sheltered or exposed suburban areas or sheltered rural areas only, for further details Download LYSAGHT KLIP-LOK MAXIMA® (881 KB).
| Maximum Support Spacing (mm) | |||
|---|---|---|---|
| Type of Span | Thickness (mm) BMT | ||
| 0.42 | 0.48 | 0.60 | |
| Roofs Single Span End Span Internal Span Walls Single Span End Span Internal Span | - 1400 2000 1900 2000 2900 | - 1800 3300 2100 2400 3300 | 2200 2600 3600 2400 3200 3900 |
The limit state wind pressure capacity table can be viewed in the LYSAGHT KLIP-LOK MAXIMA® brochure. Download LYSAGHT KLIP-LOK MAXIMA® (881 KB).
This information is suitable for use only in areas where a tropical cyclone is unlikely to occur as defined in AS1170.2-2002.
Download Using LYSAGHT® Roofing & Walling - Chapter 2 Design Preliminaries (1262 kb) to view Table 2.4.1, Maximum Roof Lengths for Drainage.
Sheets are available custom cut.
Length: +0 mm, -15 mm
Width: +2 mm, -2 mm
| BMT | Material | kg/m | kg/m2 | m2/t |
|---|---|---|---|---|
| 0.42 | ZINCALUME® | 3.26 | 4.23 | 236 |
| 0.42 | COLORBOND® | 3.34 | 4.34 | 231 |
| 0.48 | ZINCALUME® | 3.70 | 4.81 |
208 |
| 0.48 | COLORBOND® | 3.78 | 4.91 |
204 |
| 0.60 | ZINCALUME® | 4.59 | 5.96 |
168 |
| 0.60 | COLORBOND® | 4.67 | 6.06 |
165 |
| NSW/ ACT | VIC | TAS | QLD | NT | SA | WA |
|---|---|---|---|---|---|---|
| Not Avail. | Not Avail. | Not Avail. | Not Avail. | Not Avail. | Not Avail. | Avail. |
LYSAGHT KLIP-LOK MAXIMA® is available in the standard range of COLORBOND® steel colours and in unpainted ZINCALUME® steel.
Please check with your local supplier regarding specific colour availability for this product.
The maximum recommended support spacings are based on testing in accordance with AS1562.1-1992, AS4040.1-1992 and AS4040.2-1992. Supports must not be less than 1mm BMT.
Roof spans consider both resistance to wind pressure and light roof traffic (traffic arising from incidental maintenance).
Wall spans consider resistance to wind pressure only.
The figures relate only to buildings 10m or less in height and located in sheltered or exposed suburban areas or sheltered rural areas only, for further details Download LYSAGHT KLIP-LOK MAXIMA® (881 KB).
| Maximum Support Spacing (mm) | |||
|---|---|---|---|
| Type of Span | Thickness (mm) BMT | ||
| 0.42 | 0.48 | 0.60 | |
| Roofs Single Span End Span Internal Span Walls Single Span End Span Internal Span | - 1400 2000 1900 2000 2900 | - 1800 3300 2100 2400 3300 | 2200 2600 3600 2400 3200 3900 |
The limit state wind pressure capacity table can be viewed in the LYSAGHT KLIP-LOK MAXIMA® brochure. Download LYSAGHT KLIP-LOK MAXIMA® (881 KB).
This information is suitable for use only in areas where a tropical cyclone is unlikely to occur as defined in AS1170.2-2002.
Download Using LYSAGHT® Roofing & Walling - Chapter 2 Design Preliminaries (1262 kb) to view Table 2.4.1, Maximum Roof Lengths for Drainage.
Sheets are available custom cut.
Length: +0 mm, -15 mm
Width: +2 mm, -2 mm
| BMT | Material | kg/m | kg/m2 | m2/t |
|---|---|---|---|---|
| 0.42 | ZINCALUME® | 3.26 | 4.23 | 236 |
| 0.42 | COLORBOND® | 3.34 | 4.34 | 231 |
| 0.48 | ZINCALUME® | 3.70 | 4.81 |
208 |
| 0.48 | COLORBOND® | 3.78 | 4.91 |
204 |
| 0.60 | ZINCALUME® | 4.59 | 5.96 |
168 |
| 0.60 | COLORBOND® | 4.67 | 6.06 |
165 |