LYSAGHT PANELRIB® has a fluted profile making it suitable for many applications where flat sheet would not normally be considered. The longitudinal flutes provide rigidity along the length of the sheet while retaining full flexibility across the width.
LYSAGHT PANELRIB®
LYSAGHT PANELRIB® CAD Drawing File
This search will find the ten closest suppliers for the location you enter, for the selected product. Fill in each of the fields below, then click "SEARCH"
Please note this locator only contains suppliers in AUSTRALIA. If you need suppliers in other countries please contact your local BlueScope Steel office.
Fields marked with * are required
You may choose to Search for Supplier by Name
Cladding is a collective term for any sheeting that covers a building, whether it be on the roof of the building, or on the walls. Roof cladding is made from thicker steel and is rolled to a profile capable of supporting roof traffic*. In most cases, these roof claddings can also be used for walling as well. Wall cladding is made from thinner steel, rolled to a less rigid profile. They are generally not capable of supporting roof traffic, prohibiting their use as roofing.
*Some roofing is designed to be non-trafficable. Please consult the span and capacity tables of the cladding for further details.
The maximum recommended support spacings are based on testing in accordance with AS1562.1-1992, AS4040.1-1992 and AS4040.2-1992. Supports must not be less than 1mm BMT.
Wall spans consider resistance to wind pressure only.
The figures relate only to buildings 10m or less in height and located in sheltered or exposed suburban areas or sheltered rural areas only, for further details Download LYSAGHT PANELRIB® (794 KB).
| Maximum Support Spacings (mm) | ||
|---|---|---|
| Type of Span | Thickness (mm) BMT | |
| 0.35 | 0.42 | |
| Walls Single Span End Span Internal Span Overhang | 1100 1200 1200 150 | 1200 1200 1200 150 |
The limit state wind pressure capacity table can be viewed in the LYSAGHT PANELRIB® brochure. Download LYSAGHT PANELRIB® (794 KB).
This information is suitable for use only in areas where a tropical cyclone is unlikely to occur as defined in AS1170.2-2002.
LYSAGHT PANELRIB® is available in custom cut lengths to suit the application requirements. Check with your local supplier on the maximum and minimum available lengths.
Length: +0mm, -15mm
Width: +0mm, -4mm
| Masses (Based on 850 cover) | kg/m | kg/m2 | m2/t |
|---|---|---|---|
| 0.35 ZINCALUME® | 2.74 | 3.23 | 310 |
| 0.35 COLORBOND® | 2.80 | 3.29 | 304 |
| 0.42 ZINCALUME® | 3.26 | 3.83 | 261 |
| 0.42 COLORBOND® | 3.32 | 3.90 | 256 |
| NSW/ ACT | VIC | TAS | QLD | NT | SA | WA |
|---|---|---|---|---|---|---|
| Avail. | Avail. | Avail. | Avail. | Avail. | Avail. | Avail. |
LYSAGHT PANELRIB® is available in a limited range of COLORBOND® steel colours and in unpainted ZINCALUME® steel.
Please check with your local supplier regarding specific colour availability for this product.
LYSAGHT PANELRIB®
LYSAGHT PANELRIB® CAD Drawing File
Cladding is a collective term for any sheeting that covers a building, whether it be on the roof of the building, or on the walls. Roof cladding is made from thicker steel and is rolled to a profile capable of supporting roof traffic*. In most cases, these roof claddings can also be used for walling as well. Wall cladding is made from thinner steel, rolled to a less rigid profile. They are generally not capable of supporting roof traffic, prohibiting their use as roofing.
*Some roofing is designed to be non-trafficable. Please consult the span and capacity tables of the cladding for further details.
The maximum recommended support spacings are based on testing in accordance with AS1562.1-1992, AS4040.1-1992 and AS4040.2-1992. Supports must not be less than 1mm BMT.
Wall spans consider resistance to wind pressure only.
The figures relate only to buildings 10m or less in height and located in sheltered or exposed suburban areas or sheltered rural areas only, for further details Download LYSAGHT PANELRIB® (794 KB).
| Maximum Support Spacings (mm) | ||
|---|---|---|
| Type of Span | Thickness (mm) BMT | |
| 0.35 | 0.42 | |
| Walls Single Span End Span Internal Span Overhang | 1100 1200 1200 150 | 1200 1200 1200 150 |
The limit state wind pressure capacity table can be viewed in the LYSAGHT PANELRIB® brochure. Download LYSAGHT PANELRIB® (794 KB).
This information is suitable for use only in areas where a tropical cyclone is unlikely to occur as defined in AS1170.2-2002.
LYSAGHT PANELRIB® is available in custom cut lengths to suit the application requirements. Check with your local supplier on the maximum and minimum available lengths.
Length: +0mm, -15mm
Width: +0mm, -4mm
| Masses (Based on 850 cover) | kg/m | kg/m2 | m2/t |
|---|---|---|---|
| 0.35 ZINCALUME® | 2.74 | 3.23 | 310 |
| 0.35 COLORBOND® | 2.80 | 3.29 | 304 |
| 0.42 ZINCALUME® | 3.26 | 3.83 | 261 |
| 0.42 COLORBOND® | 3.32 | 3.90 | 256 |
| NSW/ ACT | VIC | TAS | QLD | NT | SA | WA |
|---|---|---|---|---|---|---|
| Avail. | Avail. | Avail. | Avail. | Avail. | Avail. | Avail. |
LYSAGHT PANELRIB® is available in a limited range of COLORBOND® steel colours and in unpainted ZINCALUME® steel.
Please check with your local supplier regarding specific colour availability for this product.