LYSAGHT KLIP-LOK 700 HI-STRENGTH® is a wide-cover concealed fixed cladding with no exposed fasteners for weathertight roofs. Visually, a bold rib makes a strong statement rising from the flat pans. Thermal expansion of long, straight runs are acheivable, and with no exposed fasteners, the long, straight lines remain clean and smooth.
LYSAGHT KLIP-LOK 700 HI-STRENGTH®
LYSAGHT® Long Distance Roofing
LYSAGHT KLIP-LOK 700 HI-STRENGTH® CAD Drawing File
This search will find the ten closest suppliers for the location you enter, for the selected product. Fill in each of the fields below, then click "SEARCH"
Please note this locator only contains suppliers in AUSTRALIA. If you need suppliers in other countries please contact your local BlueScope Steel office.
Fields marked with * are required
You may choose to Search for Supplier by Name
| NSW/ ACT | VIC | TAS | QLD | NT | SA | WA |
|---|---|---|---|---|---|---|
| Avail. | Avail. | Avail. | Avail. | Not Avail. | Avail. | Not Avail. |
LYSAGHT KLIP-LOK 700 HI-STRENGTH® is available in the standard range of COLORBOND® steel colours and in unpainted ZINCALUME® steel.
Please check with your local supplier regarding specific colour availability for this product.
The maximum recommended support spacings are based on testing in accordance with AS1562.1-1992, AS4040.0-1992 and AS4040.1-1992.
Roof spans consider both resistance to wind pressure and light roof traffic (traffic arising from incidental maintenance).
Wall spans consider resistance to wind pressure only.
For further details Download LYSAGHT KLIP-LOK 700 HI-STRENGTH® (1240 KB).
| Maximum Support Spacing (mm) | |||
|---|---|---|---|
| Type of Span | Thickness (mm) BMT | ||
| 0.42 | 0.48 | 0.60† | |
| Roofs Single Span End Span Internal Span Unstiffened Eaves Overhang Stiffened Eaves Overhang Walls Single Span End Span Internal Span Overhang |
1650 1750 2200 150 450 2600 3200 3850 150 |
2050 2350 2800 200 500 3000 3450 3900 200 |
2350 3000 3600 250 550 3300 3600 3900 250 |
The limit state wind pressure capacity table can be viewed in the LYSAGHT KLIP-LOK 700 HI-STRENGTH® brochure. Download LYSAGHT KLIP-LOK 700 HI-STRENGTH® (1240 KB).
This information is suitable for use only in areas where a tropical cyclone is unlikely to occur as defined in AS1170.2-2002.
For correct specification and installation of BlueScope Lysaght roofing and walling products in cyclonic areas, please Download LYSAGHT® Cyclonic Area Design Manual Steel Roofing & Walling (861 KB).
Download Using LYSAGHT® Roofing & Walling - Chapter 2 Design Preliminaries (629 kb) to view Table 2.4.1, Maximum Roof Lengths for Drainage.
Mobile rollformed sheets are custom cut on-site. Factory sheets cut to order.
Length: +0 mm, -15 mm
Width: +4 mm, -4 mm
Make allowance for thermal expansion or contraction for long length roofs at sheeting ends.
The equation ΔL = α x ΔT x L gives an indication of the sheeting extent or contraction (ΔL).
α = 12 x 10-6 (coefficient of linear expansion for steel).
ΔT = temperature change in °C.
L = sheet length in mm
LYSAGHT KLIP-LOK 700 HI-STRENGTH® is made from:
The base metal thicknesses are 0.42, 0.48 (and 0.60mm mobile rollformer only).
The COLORBOND® prepainted steel complies with AS/NZS 2728:2007.
| BMT | Material | kg/m | kg/m2 | m2/t |
|---|---|---|---|---|
| 0.42 | ZINCALUME® | 3.26 | 4.66 | 215 |
| 0.42 | COLORBOND® | 3.32 | 4.74 | 211 |
| 0.48 | ZINCALUME® | 3.70 | 5.29 | 189 |
| 0.48 | COLORBOND® | 3.76 | 5.37 | 186 |
| 0.60* | ZINCALUME® | 4.59 | 6.55 | 153 |
| 0.60* | COLORBOND® | 4.64 | 6.63 | 151 |
* 0.60 BMT available from mobile rollformer only.
BlueScope Lysaght has produced a clip which allows LYSAGHT KLIP-LOK 700 HI-STRENGTH® to be removed without damage. The clip also makes the sheets easier to install. For more information visit our page Major Breakthrough In Roofing Technology.
No. LYSAGHT KLIP-LOK 700 HI-STRENGTH® has a rib shape and clip design different to the traditional LYSAGHT KLIP-LOK® 406.
The special locating tabs on the spacer bar of the LYSAGHT KLIP-LOK 700 HI-STRENGTH® clip can be flattened easily to allow adjustment during installation.
Cladding is a collective term for any sheeting that covers a building, whether it be on the roof of the building, or on the walls. Roof cladding is made from thicker steel and is rolled to a profile capable of supporting roof traffic*. In most cases, these roof claddings can also be used for walling as well. Wall cladding is made from thinner steel, rolled to a less rigid profile. They are generally not capable of supporting roof traffic, prohibiting their use as roofing.
*Some roofing is designed to be non-trafficable. Please consult the span and capacity tables of the cladding for further details.
| NSW/ ACT | VIC | TAS | QLD | NT | SA | WA |
|---|---|---|---|---|---|---|
| Avail. | Avail. | Avail. | Avail. | Not Avail. | Avail. | Not Avail. |
LYSAGHT KLIP-LOK 700 HI-STRENGTH® is available in the standard range of COLORBOND® steel colours and in unpainted ZINCALUME® steel.
Please check with your local supplier regarding specific colour availability for this product.
The maximum recommended support spacings are based on testing in accordance with AS1562.1-1992, AS4040.0-1992 and AS4040.1-1992.
Roof spans consider both resistance to wind pressure and light roof traffic (traffic arising from incidental maintenance).
Wall spans consider resistance to wind pressure only.
For further details Download LYSAGHT KLIP-LOK 700 HI-STRENGTH® (1240 KB).
| Maximum Support Spacing (mm) | |||
|---|---|---|---|
| Type of Span | Thickness (mm) BMT | ||
| 0.42 | 0.48 | 0.60† | |
| Roofs Single Span End Span Internal Span Unstiffened Eaves Overhang Stiffened Eaves Overhang Walls Single Span End Span Internal Span Overhang |
1650 1750 2200 150 450 2600 3200 3850 150 |
2050 2350 2800 200 500 3000 3450 3900 200 |
2350 3000 3600 250 550 3300 3600 3900 250 |
The limit state wind pressure capacity table can be viewed in the LYSAGHT KLIP-LOK 700 HI-STRENGTH® brochure. Download LYSAGHT KLIP-LOK 700 HI-STRENGTH® (1240 KB).
This information is suitable for use only in areas where a tropical cyclone is unlikely to occur as defined in AS1170.2-2002.
For correct specification and installation of BlueScope Lysaght roofing and walling products in cyclonic areas, please Download LYSAGHT® Cyclonic Area Design Manual Steel Roofing & Walling (861 KB).
Download Using LYSAGHT® Roofing & Walling - Chapter 2 Design Preliminaries (629 kb) to view Table 2.4.1, Maximum Roof Lengths for Drainage.
Mobile rollformed sheets are custom cut on-site. Factory sheets cut to order.
Length: +0 mm, -15 mm
Width: +4 mm, -4 mm
Make allowance for thermal expansion or contraction for long length roofs at sheeting ends.
The equation ΔL = α x ΔT x L gives an indication of the sheeting extent or contraction (ΔL).
α = 12 x 10-6 (coefficient of linear expansion for steel).
ΔT = temperature change in °C.
L = sheet length in mm
LYSAGHT KLIP-LOK 700 HI-STRENGTH® is made from:
The base metal thicknesses are 0.42, 0.48 (and 0.60mm mobile rollformer only).
The COLORBOND® prepainted steel complies with AS/NZS 2728:2007.
| BMT | Material | kg/m | kg/m2 | m2/t |
|---|---|---|---|---|
| 0.42 | ZINCALUME® | 3.26 | 4.66 | 215 |
| 0.42 | COLORBOND® | 3.32 | 4.74 | 211 |
| 0.48 | ZINCALUME® | 3.70 | 5.29 | 189 |
| 0.48 | COLORBOND® | 3.76 | 5.37 | 186 |
| 0.60* | ZINCALUME® | 4.59 | 6.55 | 153 |
| 0.60* | COLORBOND® | 4.64 | 6.63 | 151 |
* 0.60 BMT available from mobile rollformer only.
So we can help you find the information you're looking for, please indicate your user type above>
In case you ever need to change your user type simply click the link at the top of the site.